The Energy Networks Association (ENA) represents the interests of all energy companies in the UK. The Document Catalogue System is an online catalogue of engineering documents available from the ENA.
Documents available from the site include Technical Specifications, Engineering Recommendations and Reports, BEBS Specifications and reports supporting the electricity network process and policies.
Most documents are available to anybody but a small number are confidential to ENA member companies and can only be accessed by those member companies. The system allows clients that are not full ENA members to purchase documents by credit/debit card via secure transactions provided by WorldPay.
Energy Networks Association Limited4 More London RiversideLondon SE1 2AU
Tel: +44 (0)20 4599 7700Email: [email protected]
WARNING! Some of the older (pre 2003) documents available on this site were originally published by the now defunct Electricity Association. Please note that the ENA cannot take responsibility for the condition and content of these older documents and you are advised to seek advice before acting upon information held in them.
Distributed Generation Connection Guide: G98 & G99
Low voltage heat-shrinkable material components for use up to and including 600/1 000 V
Emergency rated system transformers 66/20.5 kV, 66/11.5 kV and 33/11.5 kV delta/star and star/star connected
Low voltage overhead line shrouding materials
Aerial Bundled Conductors Insulated with Cross-Linked Polyethylene for Low Voltage Overhead Distribution
Fault Passage Indicators up to 132kV for Underground and Overhead Distribution Systems
Operational procedure associated with electricity supplies for traction purposes on AC and DC electrified lines
Code of practice for the coordination of power line carrier system frequencies in the range 30•0 kHz to 526•5 kHz
Issue 3 - Amendment 8
Recommendations for the Connection of Generating Plant to the Distribution Systems of Licensed Distribution Network Operators
Recommendations for the safe working of utilities’ staff and other parties near light rapid transit systems
Issue 1 – Amendment 10
Requirements for the connection of generation equipment in parallel with public distribution networks on or after 27 April 2019
Technical Requirements for Customers’ Export and Import Limitation Schemes
Specification for single circuit overhead pole lines for use at high voltage up to and including 33 kV
Guidance on the application of Engineering Recommendation P2, Security of Supply
Security of Supply
Environmental classification and corrosion protection of structures, plant and equipment
Structural testing of wood poles prior to climbing or use as a personal support
Tests on power cables with XLPE insulation and metallic sheath and their accessories, for rated voltages of 66 kV (Um = 72.5 kV), 110 kV (Um 123 kV) and 132 kV (Um = 145 kV)
Guidance on Neutral Current Diversion
400 V a.c. switchgear, controlgear and fusegear assemblies
Public Electricity Network Distribution Assemblies
Outdoor, free standing CTs & VTs up to 36 kV
Design and use of temporary scaffold guards and conductor support systems
Insulated Aerial Bundled Conductors for Low Voltage Overhead Distribution Systems – Erection Requirements
Covered-conductors for overhead lines (having rated Voltages Uo/U greater than 0.6/1 kV up to and including 19/ 33 kV)
Stay strands and stay fittings for overhead lines
Earth rods and their connectors
Environmental test requirements for protection and control equipment and systems
Application of ancillary electrical equipment
Standard numbering for small wiring (for switchgear and transformers together with their associated relay panels)
Engineering Recommendation G100 Issue 2 Overview and Summary Guide
Requirements for the Application of Protective Multiple Earthing to Low Voltage Networks
National Equipment Defect Reporting Scheme (NEDeRS®) – Notes of guidance
Overhead line conductors - protection against corrosion by the application of anti-corrosion grease during manufacture
Insulating foam-filled tube and solid rod for live working
Guidance for the operation and management of fluid filled cables. This document replaces ETR 135.
Distribution cables of rated voltage 0.6/1/ (1.2) kV with XLPE insulation, concentric waveform copper wire and solid aluminium conductors
Guidelines for the Provision of Low Voltage Connections to Multiple Occupancy Buildings
Switchgear for use on 66 kV to 132 kV distribution systems Part 5 Inductive voltage transformers, capacitor voltage transformers, combined unit transformers and current transformers for use on 72.5 kV to 145 kV distribution systems
Switchgear for use on 66 kV to 132 kV distribution systems (Disconnectors and earthing switches)
Measures necessary to minimise corrosion damage to buried metallic structures by neighbouring cathodic protection installations
Power installations exceeding 1 kV a.c. – Design of high-voltage open-terminal stations
Aerial bundled conductors insulated with cross-linked polyethylene for low voltage overhead distribution
Specification for single circuit overhead lines of compact covered construction on wood poles for use at high voltage up to and including 33 kV
XLPE covered-conductors for overhead lines (having rated voltages Uo/U greater than 0.6/1 kV up to and including 19/33 kV)
Partial discharge testing of bushings, capacitors, instrument transformers and switchgear of rated voltage 7.2 - 420 kV inclusive
Single core cables for use in substations having extruded insulation and rated voltages of 6350/11 000 volts, and 19 000/33 000 volts
Type approval tests for mechanical connections to metallic sheaths of cables Addendu
Distribution transformers - Part 4 Pole mounted transformers
Fittings for covered conductors for overhead lines (having rated voltages U0/U greater than 0.6/1 kV up to and including 19/33 kV)
Portable earthing equipment for overhead lines and substations
Switchgear for service up to 36 kV (Cable and Overhead conductor connected)
Complexity of Distribution Circuits Operated at or above 22kV
Specification for single circuit overhead lines on wood poles for use at 132kV
Guide to the application of Engineering Recommendation G5/4 in the assessment of harmonic voltage distortion and connection of non-linear equipment to the electricity supply system in the U.K
Calculation of fault currents in three-phase AC power systems (Application Guide to Engineering Recommendation G74)
Analysis package for assessing the security contribution from distributed generation and electricity storage systems – Users’ guide
Analysis Package For Assessing Generation Security Capability - Users' Guide
Harmonic voltage distortion and the connection of harmonic sources and/or resonant plant to transmission systems and distribution networks in the United Kingdom
Amendment 7
Issue 2 Amendment 3 Recommendations for the Connection of Type Tested Small-scale Embedded Generators (Up to 16A per Phase) in Parallel with Low-Voltage Distribution Systems
Issue 1 Amendment 4 Requirements for the connection of generation equipment in parallel with public distribution networks on or after 27 April 2019
Voltage fluctuations and the connection of disturbing equipment to transmission systems and distribution networks in the United Kingdom
EREC G99/NI - Northern Ireland Only
Requirements for the connection of generation equipment in parallel with public distribution networks in Northern Ireland on or after 27 April 2019
Guidelines for the design, installation, testing and maintenance of main earthing systems in substations
A guide for assessing the rise of earth potential at electrical installations
Framework for new low voltage housing development installations - Part 1 Design and planning
Framework for new low voltage housing development installations - Part 2 Materials specification
Framework for new low voltage housing development installations - Part 3 Installation and records
Framework for new industrial and commercial underground connections - Part 4 Design and planning
Framework for new industrial and commercial underground connections - Part 5 Materials specification
Framework for new industrial and commercial underground connections - Part 6 Installation and records
Framework for contestable diversionary and reinforcement works not exceeding 33 kV - Part 7 Contestable diversionary and reinforcement works
Air break switch disconnectors and expulsion fuses: Recommendations
This EREC specifies the ratings applicable to overhead conductor connected air break switch disconnectors (ABSDs) from 7.2 kV to 36 kV, together with some technical requirements. It also recommends ratings that may be applicable to expulsion fuses in some circumstances. This EREC excludes ABSDs incorporated in metal-clad or cellular type switchgear. It also excludes other types of overhead conductor connected fusegear. From Issue 4 of this EREC, the ratings given in the appropriate tables are only applicable to legacy devices. New devices shall conform to the relevant clauses of TS 41-47 [N1]. NOTE: Legacy devices are those air break switch disconnectors that are already installed and in use on the UK electricity distribution network, or have already been procured and are in store awaiting installation. This EREC covers typical operational practices and safety precautions, and for convenience includes suggested methods of identification and marking that continue to be used 45 throughout the industry.
Issue 4 June, 2021 Minor revision to Issue 3 to include guidance on ratings for expulsion fuses This issue includes the following principal technical changes. Document title changed to reflect amended scope and now includes guidance on expulsion fuses Clause 3, Terms and definitions: Additional definitions (3.3, 3.5 – 3.11) added to improve clarity of the document. New Clause 4, Categories of devices: Descriptions of categories 0,1,2 and 3 have been subject to clarification using the new terms (Clause 3). The intent is to simplify the description. There is no technical change from previous Issue. Clause 6, ABSD ratings: New clause title added to differentiate ABSDs from expulsion fuse ratings (which are in an Annex A). Cross references to tables have been updated. Inclusion of the term ‘independent operation’ in final paragraph to improve clarity. Clause 8, Operation: In para 1, the word ‘shall’ has been changed to ‘should’ in respect of staff receiving adequate and appropriate training – this change reflects the intent of the document being a guide. A new para 2 has been added to consider use of ‘portable current interruption devices when operating ABSDs and expulsion fuses’. Para 2 is accompanied with a NOTE. New paras 3,4 and 5 have been added providing guidance on ferroresonance when disconnecting expulsion fuses. Clause 10, new sub-clauses added regarding category identification and recording. New Table 1.5, Expulsion fuses: suggested making and breaking duty. New Annex A – Guidance on assigning ratings to expulsion fuses. Includes fault making duty and load breaking duty. New Annex C added. Typical procedure for operating expulsion fuse. New Bibliography inserted to capture informative reference (ENA ACE Report 75)
If you are already registered on the catalogue, you are advised to login for your own convenience. You are welcome to browse the catalogue as a guest if you prefer but you must be logged in to complete an order ( Why? ).
New visitors to the catalogue can register immediately if preferred but it is equally convenient for most to browse the catalogue as a guest and register if going on to order a document.
Users from ENA member (full/associate) companies are entitled to benefits. New member users should register as such and wait for confirmation that their registration has been approved before placing orders.
Please note that all orders are completed by email.
forgotten password Remember Me